Pump Controllers
A major strength of Best Controls Company is our ability to design and build dedicated controllers for the wastewater industry. These controllers are heavy-duty in design and have numerous features that reduce the amount of field expertise needed to operate the systems.
PC-0500 / PC-1000 / PC-2000 / PC-3000
PC-0500 Simplex Controller
PC-0500 Features:

• Simplex Pump Controller
• Power Input: Fused & Transient Protected
• Float Inputs (Three): 5Vdc @ 1Ma Max
• Float & Sensor Inputs Transient Protected
• Pump Run & Pump Call Indicator Lights
• Hand-Off-Auto Switch
• Pump Seal Fail Input w/ Indicator Light
• Pump Over Temperature Imput w/ Indicator Lights
• High Level Alarm Indicator Light
• Alarm Test Push Button
• Removable "Quick Connect" Terminal Strips For Easy Service
• Output For Flashing Alarm Light

PC-0500 Specifications

PC-0500 / PC-1000 / PC-2000 / PC-3000
PC-1000
Duplex Controller
PC-1000
Features:

• Duplex Pump Controller
• Power Input: Fused & Transient Protected
• Float Inputs (Four): 5Vdc @ 1Ma Max
• Float & Sensor Inputs Transient Protected
• Pump Run & Pump Call Indicator Lights
• Hand-Off-Auto Switches
• Pump Seal Fail Inputs w/ Indicator Lights
• Pump Over Temperature Imputs w/ Automatic Disable & Indicator Lights
• High Level Alarm Indicator Light
• Alarm Test Push Button
• Pump Alternation Selector Switch
• Removable "Quick Connect" Terminal Strips For Easy Service
• Automatically Demote Pump With Seal Fail Condition To Lag Pump
• Built-In Delay For Pump Starts & Pump Stops
• Output For Flashing Alarm Light

PC-1000 Specifications

PC-0500 / PC-1000 / PC-2000 / PC-3000
PC-2000 Duplex Controller
PC-3000
Features:
* Indicates Additional Features of PC-2000 over the PC-1000

• Power Input: Fused & Transient Protected
• Float Inputs (Five): 5Vdc @ 26Ma Max
• Float & Sensor Inputs Transient Protected
• Pump Run Lights
• Pump Alternation Switch
• Pump Seal Fail Inputs w/ Indicator Lights
• Pump Over Temperature Inputs w/ Automatic Disable & Indicator Lights
• Switch Selectable For Latch To Requires Manual Reset
• Output For Flashing Alarm Light
• Relay Output For Alarm Horn w/ Mute Reset Or Common Alarm
• High Alarm Indicator Light
• Low Alarm Indicator Light
• "Push-To-Test" Float Switches w/ Indicator Lights
• Float "Out Of Order" Detection w/ Indicator Lights
• "Fail To Start" Test (Switch Selectable - Enable/Disable)
• Pump Disable Inputs (Can Be Used For SCADA, etc.)
• Optional Serial Port For Communication (Modbus)
• Built-In Delay For Pump Starts & Pump Stops
• Automatically Demote Pump With Seal Fail Condition To Lag Pump
• Removable "Quick Connect" Terminal Strips

*





*

*

*
*
*
*
*
*
PC-2000 Specifications

PC-0500 / PC-1000 / PC-2000 / PC-3000
PC-3000 Simplex, Duplex or Triplex Controller

• 32 character alpha-numeric liquid crystal display for level, status, and setpoint information
• Alternation selection switch on front panel to turn alternation on or select the lead pump is alternation is off
• Simple menu structure for easy display and modification of setpoints and setup configuration
• Built in elapsed time meters for all pumps
• 4-20mA. main sensor input with loop power supply for easy connection to most transducers and transmitters
• Pump Seal Fail and Over Temp Inputs w/ Indication
• Scalable 4-20mA. level output transmitter
• Built in single float backup system
• Three auxillary inputs
• Built in horn relay with input for external mute button
• Relay outputs for both high and low level alarms
• Individually selectable setpoints for up to three pumps
• All inputs are filtered and transient protected
• Built in software, no programming required

PC-3000